Ceiling Suspended LAF
A ceiling suspended laminar air flow unit hangs above a filling line, machine or open process zone and bathes it in HEPA-filtered air, without taking any floor space..
View details →Laminar air flow units give you an ISO-class clean work zone by pushing H14 HEPA-filtered air across the work surface in one steady direction. We build horizontal, vertical and equipment-sized LAFs in stainless steel, and supply them across India and Gujarat.

Inside a laminar air flow (LAF) unit, a blower pulls room air through an EU-6 pre-filter, then pushes it through a mini-pleat H14 HEPA filter that captures 99.999% of particles at 0.3 µm. The clean air leaves the filter face in parallel streams at 0.45 ± 0.05 m/s and sweeps contaminants away from the product.
We make three types: vertical LAF, where air flows down onto the work surface; horizontal LAF, where it flows from the back of the bench toward the operator; and LAF for equipment storage, built around a machine or rack so it stays under clean air between uses. For large areas over a filling line, see our ceiling suspended LAF.
| Airflow | Horizontal or vertical |
|---|---|
| Cabinet | SS 304 / SS 316 / MS powder coated |
| HEPA filter | Mini-pleat H14, 99.999% at 0.3 µm |
| Pre-filter | EU-6 glass fibre, 98% at 5 µm |
| Air velocity | 0.45 ± 0.05 m/s (90 ± 20 FPM) |
| Pressure gauge | Magnehelic differential |
| Blower | Variable-speed centrifugal or backward-curved |
| Work surface | SS 304 |
| Power | Single phase, 220 V, 50 Hz |
Specifications are standard values; final details are confirmed on the approved drawing.
An LAF protects the product only: filtered air flows out toward the operator. If you handle biological agents, pathogens or anything hazardous, you need operator protection too, which a biosafety cabinet provides. For powder handling with operator protection, use a reverse laminar air flow (RLAF) booth.



Every order is fabricated and inspected at our plant on Kathwada GIDC Road, Ahmedabad.
Share room details, sizes, drawings or a product list.
We propose a design and send drawings with the quotation.
SS cutting, bending, welding and finishing under one roof.
Stage-wise quality checks before dispatch.
Packed for safe road and export transit.
Vertical LAF blows filtered air down onto the work surface; horizontal LAF blows it from the back of the bench toward the operator. Vertical units are often preferred where the operator should not be in the air path.
A mini-pleat H14 HEPA filter rated 99.999% at 0.3 µm, with an EU-6 pre-filter rated 98% at 5 µm.
Yes. We are based in Ahmedabad and supply across Gujarat and the rest of India.
Share your requirement, drawings or questions about laminar air flow. We usually reply with options and a quotation.
A ceiling suspended laminar air flow unit hangs above a filling line, machine or open process zone and bathes it in HEPA-filtered air, without taking any floor space..
View details →A reverse laminar air flow unit protects the person and the product at the same time.
View details →Biological safety cabinets that protect the operator, the sample and the laboratory during work with biological agents.
View details →When materials move into a higher-grade cleanroom, a dynamic pass box purges the chamber with HEPA-filtered air before the clean-side door opens.
View details →Send it to us. Our team will reply with options, drawings and a quotation.