Static Pass Box
A static pass box is the simplest way to move materials between two rooms of the same cleanliness grade.
View details →When materials move into a higher-grade cleanroom, a dynamic pass box purges the chamber with HEPA-filtered air before the clean-side door opens. We build them in SS 304/316 with H14 HEPA filtration, magnehelic gauges and interlocked doors.

A dynamic pass box works like a small laminar air flow chamber in the wall. A variable-speed centrifugal blower draws air through an EU-6 pre-filter and an H14 HEPA filter and re-circulates it through the chamber at 0.45 ± 0.05 m/s. Particles that came in on the material are swept away before the inner door unlocks.
A magnehelic differential pressure gauge shows when the filter is loading up, and a digital pressure gauge with alarm is available. The doors use the same electromagnetic interlock, UV germicidal light and white light as our static pass boxes.
| Material | SS 304 / SS 316 |
|---|---|
| Filtration | Re-circulated; H14 HEPA + EU-6 pre-filter |
| Air velocity | 0.45 ± 0.05 m/s (90 ± 20 FPM) |
| Pressure gauge | Magnehelic differential |
| Blower | Centrifugal, variable speed |
| Interlock | Electromagnetic |
| Lighting | White + UV germicidal |
| Sound level | Below 65 dB |
| Power | Single phase, 220 V, 50 Hz |
Specifications are standard values; final details are confirmed on the approved drawing.



Every order is fabricated and inspected at our plant on Kathwada GIDC Road, Ahmedabad.
Share room details, sizes, drawings or a product list.
We propose a design and send drawings with the quotation.
SS cutting, bending, welding and finishing under one roof.
Stage-wise quality checks before dispatch.
Packed for safe road and export transit.
Choose a dynamic pass box when material moves from a lower-grade area into a higher-grade cleanroom, so the chamber can be flushed with HEPA-filtered air first.
An H14 HEPA filter with an EU-6 pre-filter, mounted with an SS 304 flange.
0.45 ± 0.05 m/s (90 ± 20 FPM).
Share your requirement, drawings or questions about dynamic pass box. We usually reply with options and a quotation.
A static pass box is the simplest way to move materials between two rooms of the same cleanliness grade.
View details →Stainless steel pass boxes that move materials between rooms of different cleanliness without letting air, dust or microbes follow them through.
View details →Laminar air flow units give you an ISO-class clean work zone by pushing H14 HEPA-filtered air across the work surface in one steady direction.
View details →Biological safety cabinets that protect the operator, the sample and the laboratory during work with biological agents.
View details →Send it to us. Our team will reply with options, drawings and a quotation.